Investigation of Defects in Fully Packaged Devices
- Integrated Circuits - - An Online Book - |
||||||||
| Integrated Circuits http://www.globalsino.com/ICs/ | ||||||||
| ================================================================================= | ||||||||
LIT can be used to investigate fully packaged devices since thermal waves can propagate through optically opaque materials like mold compounds. Using a lock-in frequency of 1 to 25 Hz allows the observation of hot spots through 100-400 µm package material with a lateral spot size of a few tens to hundred µm. Figure 4902 shows an example of using LIT for defect localization in a fully-packaged device. A defect causing a short between these two Au bond wires had been detected.
[1] Paiboon Tangyunyong and Christian Schmidt, Thermal Defect Detection Techniques, Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.
|
||||||||
| ================================================================================= | ||||||||
|
|
||||||||